Tap Troubles

The humble box spanner
There was a time when if you wanted to fit a basin or bath tap you would dig out your standard half inch or three-quarter inch box spanner and tighten or remove the tap's back-nut with little or no bother. Alas, it would appear that those days are gone!

There's been a spate of taps entering the UK market recently that are no longer supplied with what I would call a standard back-nut. It's almost impossible to see if you are going to have an issue from just looking at the nut but when you try to tighten it using a standard tap box spanner it doesn't fit! I guess this could be a manufacturing error but it seems to be so commonplace that I'm assuming they are now using some metric version of the back-nut, a version that is exactly too big to work with the old Imperial box spanner.

The most annoying aspect of this is that not only do they not tell you this when you buy the tap but, because they are so similar in size, you don't get to realise there is an issue until you're stuck underneath the bath trying tighten up your new taps and failing dismally. It wouldn't be so bad if there was an alternative tool to use but, aside from a basin spanner, which is awkward to use at the best of times, there isn't. Occasionally you might be able to get by using an adjustable spanner but more often than not that's just not possible.

I dare say you be able to buy a new metric box spanner for these new taps in the not too distant future but for now it's just plain old-fashioned annoying, although you should be able to get around it by retaining the old back-nuts from the taps you've just taken off, so don't throw anything away until the new taps are on nice and tight.

Wednesday, 28 September 2016

Latest Updates

Chrome
 Change seems to happen all at once or not at all in the plumbing world. Since the 1st Edition of the "Home Plumbing" manual not a great deal has changed. Ok, my prediction that the drain cock with a spherical valve rather than a washer would take off did not come to fruition, in fact it seems to have trudged off to a dark corner and quietly died a death.

So what has actually changed in the last few years? Well, for me at least, the two big advances have been the introduction of 'Layflat' pipe and connectors that mean that Chrome wastes are no longer the stuff of nightmares.

LayFlat Pipework

'Layflat' is not an apt description of the product, rather it is a marketing statement stuffed full of wishful thinking. An apt description of the product would run something along the lines of "Far less likely to take your eye out as it whips back into a coil" but I guess they'd have to sell it in bigger coils if they were going to get all that on the side of the box, so 'Layflat' it is.

The big advantage of plastic is that you can thread it through holes in the centre of your joists. As a result, your pipework is well away from errant hammers and nails, the joist isn't weakened anywhere near as much as it would have been if you'd notched it, and  you can avoid having umpteen joints in your pipework, which is always going to be a weak spot no matter how good your soldering.

Even better is that you can buy plastic pipework in really long coils, so that you can avoid joints all together if you need to. The downside of these coils was that, once coiled, the pipework was very reluctant to uncoil. This was a pain if you wanted to thread it through 3m of joists, a real pain for 5m and an absolute agony for really long runs.

I'm fairly sure that it was John Guest that first came out with this new type of plastic pipe but most of the plastic pipe companies seem to have a similar offering these days. I recently discovered a coil of the old pipework at the back of our lock-up and I'd forgotten just how awkward it was to use, especially if you're working on your own, compared to the new stuff.

I think they have now stopped selling the old pipework, so all plastic pipework - certainly that sold by John Guest - is this new 'Layflat' pipe, a change for which you should be eternally grateful.

Chrome Fittings
Solvent-weld to chrome, nicely done


In the manual I mentioned that chrome is a complete pain to work with. This isn't because it's very poor at transporting water and waste - although it's not the greatest. It's a pain because it never used to fit anything else very well.

The whole point of Chrome is that it looks nice so, if you are going to use it, you need the end result to look nice and shiny and neat. The problem was that sooner rather than later you needed to change from chrome to plastic pipework and that was never, ever, a nice, shiny or neat change.

You really only had two options: fit the chrome into plastic push-fit pipework or use a compression connector.

The problem with using plastic push-fit is that it's not really designed for this diameter of pipe and, whilst chrome pushes-into push-fit fittings easily enough, it also pulls back out again with little or no encouragement. This is bad enough when you can see the problem but when you hide the push-fit behind stud walls and under floorboards you are just asking for trouble.

Compression fittings aren't much better because they are huge and ugly and, once again, the chrome pipework can be pulled out again fairly easily - because the chrome pipework is slightly narrower and because chrome is pretty slippy stuff.

To add to the frustration, what you wanted your chrome pipework to join to - solvent-weld plastic - it obstinately refused to do so.

The end result was that I avoided Chrome pipework like the plague. Sadly, whilst the Black Death hasn't darkened my doorstep since the 1600's, Chrome keeps cropping up all the bloody time and has to be dealt with.

Fortunately those lovely people at McAlpine have come to the rescue with a series of fittings designed specifically for chrome waste pipework. This includes general chrome fittings, designed specifically for Chrome Waste pipework, lengths of chrome pipe itself and, most importantly of all, adaptors to take you from chrome to solvent weld neatly and easily.

I can sleep well at night once more :)

Wednesday, 1 January 2014

Thanks for the reviews

Haynes Home Plumbing Manual
I’d just like to take advantage of the New Year celebrations to offer a large ‘thank you’ to all 29 people who have taken the time to log onto Amazon’s site and give my manual a rating, especially the 22 of you who gave it a 5 star.

Despite being a fairly eager reviewer myself I am pretty sceptical of these reviews, for the simple reason that they seem very easy to fake. So it was with some surprise that I discovered that I’d never even heard of the vast majority of my reviewers – yes one or two at the beginning were from friends, but then, at the beginning, they were the only people buying the damn thing. Since then I can say with hand on heart that I haven’t a bloody clue who these people are, although they are clearly wonderful examples of humanity with fine taste and sparkling intellect.

One of the best reviews for the manual is also the lowest star rating (3), which I think works quite well. Apparently she thought the manual was excellent but felt that I might make lots of money out of it and put plumbers out of business. Sadly, she is very wrong!

One of the many myths about writing is that you’ll make lots of money from it and sure enough some authors do seem to be doing very, very, well. Alas, this isn’t typical. In fact I’d go far as to say that taking up the pen in order to live a life of vast wealth and fame is like serving chicken at KFC because you’ve heard that there are people in the fast-food industry who are making millions.

Of course I was blissfully unaware of these financial limitations when my manual first came out. Ok, I wasn’t naive enough to think that people would be queuing up outside Waterstones at midnight, dressed as plumbers – aside from myself - but I did think that the manual would sell far better than it has.

Much of this was down to Amazon’s ranking system. By all accounts there are 6.5 million books available from Amazon, so when I saw that my manual was in the top 10,000 I naturally assumed that I was onto a winner. After all, if I was coming 10,000th in a Marathon that involved 6.5 million competitors, I’d be pretty chuffed.

Sadly, it doesn’t quite work like that. For starters most people who enter a marathon are fairly fit and have a reasonable expectation of finishing the race. The same cannot be said of many of the books offered by Amazon. To continue the analogy, many are well into their dotage, with a hacking cough, high blood pressure and a nasty limp. At least 4 million of them don’t even own a set of trainers and a couple of million are not even aware that there is a race going on, in other words, of those 6.5 million books only about 100,000 are actually being bought with any kind of regularity. At this point, whilst being ranked at 10,000th isn’t bad, it becomes clear that a lap of honour is unlikely and that medals are going to be in pretty short supply.

All in all, as a working plumber I probably make more money clearing blocked toilets during the year than I do from writing about them, which is a bit of a shame as writing is far easier on the old knees and, as a career, is almost effluent free.

On the plus side many of my own dreams have been realised; I have a published book! Ok, it involves slightly fewer buxom maidens and far more close coupled toilets than I’d originally imagined my first book would contain but at least I can say I am a published author. It also regularly outsells “A Tale of Two Cities” and Wilbur Smiths “When a Lion Feeds” and I must admit that I never thought I’d be able to say that. Ok, there is a rather large caveat here; it regularly outsells them on Amazon’s UK site. I dare say that whilst a large number of people in Japan and Brazil might be tempted to buy “When a Lion Feeds” (one of the all time favourite books from my childhood) few, if any, are going to pick up a book on UK plumbing – which I feel is a sad indictment of modern society... well maybe not.

So, once again, thanks to all those people who have bought the book and enjoyed it enough to go on-line and rate it. For those people who are merely thinking of buying the book, go for it! Don’t for one second think that the vast wealth that I’ll accrue as a result of your purchase will go to my head, cos it won’t... although I may be able to afford a bag of crisps to go with my Friday night beer down at the local, albeit not a big bag. 

Sunday, 18 November 2012

La-Co Cool Gel


To my mind “proper” plumbing uses copper tube. I’ve nothing against plastic pipework - it’s terrific stuff for quickly laying the backbone of CH systems - but it’s best hidden from view where the white, floppy, pipework and the large, knobbly, fittings can’t offend the eye.

Of course there are a few rather large problems with the alternative, copper tubing. Most of these revolve around the fact that it’s best soldered, which in turn requires a modicum of skill and risks burning down your home. Reducing your home to smouldering rubble is known within the plumbing trade as “a bad thing”... and so the heat mat was invented.

In the bad old days I suspect that heat mats were made of asbestos and lasted a life time – partly because they killed you early. These days they may be safer but they have the life expectancy of a Mayfly with a chesty cough, mainly because they can’t cope with direct heat. 
This is a real same because more often than not the time you really need a heat mat is when you have no choice but to aim your blowtorch directly at a flammable surface.

However there is an alternative to the heat mat, which is a spray on gel called “La-Co Cool Gel” which I’m fairly certain I failed to mention in the book - It’s only writing this up now  that I’ve realised it’s not called LL Cool Gel. Which is a shame as that is what I always ask for.

Cool Gel is known as a heat barrier spray and from what I can make out it’s basically water made firm by holding it in gel form.. and it’s superb! I wouldn’t spray into on carpets and the like – although it would probably work - but, aside from that it can be used everywhere else you might want to use a heat mat.

It’s also very handy if you have to heat up a pipe that is very close to a valve. The valves themselves often contain rubber washers which melt or deform when heated. To prevent this just spray the pipe with the cool gel between the valve and where you’re heating. The heat now travels as far at the gel where it is miraculously stopped in its tracks, preserving the valve whilst you solder your joint.

Alas, it’s not cheap but it is well worth the investment as it’s still considerably cheaper than a new home.

Tuesday, 31 July 2012

Bristan Easyfit


Bristan Easyfit Taps
Fitting taps is not technically difficult but the locations you have to wriggle into and under can turn what should be a simple job into a bit of a nightmare. 

As I mentioned in the Home plumbing manual, throwing away the copper pipes that come with most taps and fitting flexible tap connectors can make things much easier but it's still the kind of job that most plumbers try to avoid because it's such a pain. However, help may be on its way in the form of the new range of Bristan Easyfit taps.

Basically the tap now comes in two parts. You fit the base, which comes with flexible connectors and isolation valves, and then, when you've finished the tiling and applied your sealant lines, you fit the tap onto this base!

We had a play around with this last year up at Bristan’s offices. Yes, there were a few issues at the time but the fact that they'd made a point of asking installers to try them out and give them feedback is in itself a wonderfully sane approach to plumbing design - although sadly not one that seems to have caught on much within the industry.

Of course the main benefit of a two part tap comes later on when you need to update it or just give it a good clean. Instead of having to burrow under the basin or bath for a sweaty and frustrating half hour you can just isolate the water supply and then remove the tap body from the top and fit the new one into place. What could be simpler?

Yes, you’d have to replace the old Bristan tap with a new Bristan tap, but I can think of many more traumatic things in life.

All in all they are well worth having a look at - in fact to have a look click here: tapfittingchampionships

------- update -----

Over the last few yeas we've come across a number of customers who have had problems with these taps, mainly because the grub screw that holds the tap in place fails, the tap blows off and a deluge ensues. I have to assume that Bristan are sorting this out - more than 1 grub screw and some sort of locking mechanism would seem sensible - but I don't know for sure. With this in mind you might just want to check the grub screw every 6 months or so and just give it a little tweak to keep it in place.

Monday, 16 July 2012

hep20


Within the Haynes Home Plumbing manual I discussed at some length the pro’s and con’s of the various push-fit piping systems. 

Personally I avoid plastic pipework where I can for no other reason than I think copper looks better and is cheaper to work with – the pipes are about the same price but copper fittings are no where near the price of their plastic counterparts. That said, for the DIYer plastic piping is a Godsend.

At the time of writing Wavin had two products on offer; their old traditional Hep20 product, which could be recognised by its uninspiring battleship grey colour and the fact that you couldn’t get the fitting off with any ease once you’d managed to get it on, and their new product, which they were calling “In4Sure”.

Well a few weeks ago I popped into the local plumbing merchants to find them putting all the old grey hep20 fittings into bags for return to Wavin. It seems that two things have happened, firstly that the old grey system has been recalled and secondly that the chaps at Wavin are keen Startrek fans - In4Sure is now being heralded as the “The Next Generation hep20”. You can still find it called In4Sure but I suspect this name will be quietly dropped over the coming years to make way for “Hep20 Voyager”, and “Hep20 deep space 9”.

To be honest this is a well overdue move. The old hep20 wasn’t a patch on most of its rivals, whereas In4Sure contains a number of sound innovations that bounce it right back up there.

In terms of use nothing has changed from what I said in the book, although there are a few things that bear repetition: the pipework is nominally the same size as the competitor products (mainly Speed-fit) but it has a slightly smaller inside diameter, which means that a speed-fit pipe strengthener (or insert) can only be used if you’ve brought a hammer along for the job. In other words you can mix and match the fittings and pipes but always try to use a hep20 pipe insert for hep20 pipework and a speed-fit insert for its pipework. The other benefit of Hep20 is that the pipe itself seems far more flexible than that of its competitors, which can be very useful if you are trying to thread it through joists.

Monday, 2 July 2012

Kibosh

Put the kibosh on it.
In the Haynes Home Plumbing Manual I talked about dealing with burst pipes and suggested a clamp repair kit as a fairly useful piece of kit to keep in the home (p39). Well Rothenberger have recently brought out a neat little adaptation to this called the "Kibosh".

The principle remains the same - you open it up, place it over the leak and then clamp it shut. Of course it's only a temporary fix but it gives you time to draw breath and decide how to effect a permanent repair.

The design means that it should be relatively easy to get it onto most pipework and it's small and neat enough to rest unnoticed in kitchen drawers for years at a time without cluttering up the place.

The current Kibosh is only designed to repair 15mm pipework, which means that for the next few months  only your 22mm pipework will be prone to spontaneous bursting - for such is the law of Sod. However, different sizes will be out soon.

The 15mm version costs about £12 - when I asked at PTS they said that was the RRP so you ought to be able to beat them down a bit - but to fully cover yourself you're going to need a version for every pipe size in your home, which could make it an expensive business.

Another thing that worried me when I first saw it was that it was so small. If a pipe bursts because it froze, the ice usually causes the pipe to swell up a bit for at least 5cm on either side of the actual fracture. Can the Kibosh cope with this? Well, frankly I haven't a clue but I'd be surprised if they hadn't already considered this.

To be honest it looks a really well thought through design that's well worth buying for that rainy, floody, day.

Word of warning though - don't wait until you have a flood before reading how to use the Kibosh, have a practice first.

You can find more details at: Kibosh pipe repair


Monday, 30 April 2012


This blog is designed to accompany the Haynes Home Plumbing Manual written by Andy Blackwell.

It would be great if no one found any errors or omissions in the manual. It would also be great if I suddenly shot up to 6ft 4 and sprouted long, flowing, locks. Sadly, these two widely disparate events share one common theme – they are both very, very, unlikely to happen - to say the least. So, when an error is spotted I’ll list it here.

The manual also included a fairly extensive chapter on alternative fuels and green technologies, an area that develops at an astonishing pace. As I hear of new grants and developments I’ll be posting them here as an accompaniment to the book.

Whilst the rest of the plumbing sector might not be quite as frantic as the green/alternative fuel arena it’s certainly not static – in fact some would suggest that it just can’t stand still at the moment - so I will be continuing the blogs I wrote for yell.com and maintaining a running commentary on general plumbing news and interesting tools and developments. Rather than clog up this blog I’ll be posting this general plumbing news to Plumbforyourlife.