Wiring up a motorised valve

For most homeowners one look inside a central heating wiring centre is enough to convince them to get the professionals in, which is a shame because the most common failures in a central heating system are the pump and the motorised valves and these are both wired back to this complicated, spaghetti like, mass of wires.

Fortunately, things are getting easier. For pumps it was never that difficult, they only have 3 wires: live, neutral, earth and if you can’t manage 3 wires you really have to ask yourself if you should be doing this at all. That said, only good can come from keeping people away from the wiring centre, so these days the cable on most pumps comes with a kettle-like connector that can just be detached and plugged in to the new pump, the proviso being that you replace like-for-like.

For motorised valves, especially 3-port valves, it is a bit more intimidating. A 3-port valve has 5 wires: Neutral (blue), Earth (yellow and green), Hot Water Off (grey), Central Heating On (white) and Switched Live Out (orange). 

Fortunately, the number of wires and their colours is pretty much a standard across the industry so you can replace a 3-port or 2-port valve from one manufacturer with the valve from another manufacturer and not have to change any of the wiring in the wiring centre. On the downside, the cable supplied with the valve is usually directly wired into it and can’t be easily swapped over and if it does come with a plug the odds are that plug will only fit a valve supplied by the same manufacturer. As a result, you generally did have to replace the wiring at the wiring centre. This wasn't exactly rocket science as you just had to find the blue wire from the old valve and replace it with the blue wire from the new valve etc. But it was always fiddly work with plenty of opportunity for error.

Fortunately, there is a cheap and easy way of getting around this in the shape of Regin’s 5-way connector. It's a very simple idea, rather than take the old cable out of the wiring centre you just cut it off and fit a plug to the end of it. You then fit another plug to the cable on your new valve, push the 2 plugs together and hey presto. Not only does this make wiring up a motorised valve relatively straightforward but the connectors themselves are fairly cheap at about £6, although I'd be surprised if i they cost more than 30p to make.

To use these connectors just follow these simple steps:

Step 1
Cut the cable on the 3-port valve you are replacing (having ensured that the electricity to the central heating system has been completely switched off, that you’ve tested for this using a multimeter, and that the 3 amp fuse is currently safe and warm in your pocket)
Step 2
You should now have a loose bit of cable connected at one end to the wiring centre. Use a craft knife or a wire stripper to trim back the outer cable covering and expose the 5 wires within. Use your wire stripper to remove about 5 mm of the insulation from the end of each wire and use your fingers to twist the individual strands of copper for each wire together.
Step 3


Take one side of the 5-way connector and have a close look. You can see that each connector is numbered 1 to 3 with the centre connector being labelled as the earth and the connector next to it marked N for neutral. It doesn’t really matter where you put the other 3 wires, the only thing that matters is that you use the same number for the same colour wire on both sides of the connection. So if you put the orange wire into number 1 on one side of the connector then you must put the orange wire into number 1 for the other side.
Step 4
Having wired up our loose cable we can now wire the cable that comes with the new 3 port adapter into the other side of the connector.
Step 5
Just to be certain, push the 2 connectors together and check that the same colour wires are joining up. Note that the colours can vary a little, one might be dark blue another might be light blue, but hue and tone aside the basic colours should match up. When you’re sure, fit the cover over the connector and use the 2 screws provided to secure the cable in place. Repeat this for the other side of the connector.
Step 6
With the covers on, push the 2 connectors together. They are shaped so that they can only fit together one way. Now switch on the electricity and Bob should be your uncle




Tuesday, 2 May 2017

Tap Troubles

The humble box spanner
There was a time when if you wanted to fit a basin or bath tap you would dig out your standard half inch or three-quarter inch box spanner and tighten or remove the tap's back-nut with little or no bother. Alas, it would appear that those days are gone!

There's been a spate of taps entering the UK market recently that are no longer supplied with what I would call a standard back-nut. It's almost impossible to see if you are going to have an issue from just looking at the nut but when you try to tighten it using a standard tap box spanner it doesn't fit! I guess this could be a manufacturing error but it seems to be so commonplace that I'm assuming they are now using some metric version of the back-nut, a version that is exactly too big to work with the old Imperial box spanner.

The most annoying aspect of this is that not only do they not tell you this when you buy the tap but, because they are so similar in size, you don't get to realise there is an issue until you're stuck underneath the bath trying tighten up your new taps and failing dismally. It wouldn't be so bad if there was an alternative tool to use but, aside from a basin spanner, which is awkward to use at the best of times, there isn't. Occasionally you might be able to get by using an adjustable spanner but more often than not that's just not possible.

I dare say you be able to buy a new metric box spanner for these new taps in the not too distant future but for now it's just plain old-fashioned annoying, although you should be able to get around it by retaining the old back-nuts from the taps you've just taken off, so don't throw anything away until the new taps are on nice and tight.

Wednesday, 28 September 2016

Latest Updates

Chrome
 Change seems to happen all at once or not at all in the plumbing world. Since the 1st Edition of the "Home Plumbing" manual not a great deal has changed. Ok, my prediction that the drain cock with a spherical valve rather than a washer would take off did not come to fruition, in fact it seems to have trudged off to a dark corner and quietly died a death.

So what has actually changed in the last few years? Well, for me at least, the two big advances have been the introduction of 'Layflat' pipe and connectors that mean that Chrome wastes are no longer the stuff of nightmares.

LayFlat Pipework

'Layflat' is not an apt description of the product, rather it is a marketing statement stuffed full of wishful thinking. An apt description of the product would run something along the lines of "Far less likely to take your eye out as it whips back into a coil" but I guess they'd have to sell it in bigger coils if they were going to get all that on the side of the box, so 'Layflat' it is.

The big advantage of plastic is that you can thread it through holes in the centre of your joists. As a result, your pipework is well away from errant hammers and nails, the joist isn't weakened anywhere near as much as it would have been if you'd notched it, and  you can avoid having umpteen joints in your pipework, which is always going to be a weak spot no matter how good your soldering.

Even better is that you can buy plastic pipework in really long coils, so that you can avoid joints all together if you need to. The downside of these coils was that, once coiled, the pipework was very reluctant to uncoil. This was a pain if you wanted to thread it through 3m of joists, a real pain for 5m and an absolute agony for really long runs.

I'm fairly sure that it was John Guest that first came out with this new type of plastic pipe but most of the plastic pipe companies seem to have a similar offering these days. I recently discovered a coil of the old pipework at the back of our lock-up and I'd forgotten just how awkward it was to use, especially if you're working on your own, compared to the new stuff.

I think they have now stopped selling the old pipework, so all plastic pipework - certainly that sold by John Guest - is this new 'Layflat' pipe, a change for which you should be eternally grateful.

Chrome Fittings
Solvent-weld to chrome, nicely done


In the manual I mentioned that chrome is a complete pain to work with. This isn't because it's very poor at transporting water and waste - although it's not the greatest. It's a pain because it never used to fit anything else very well.

The whole point of Chrome is that it looks nice so, if you are going to use it, you need the end result to look nice and shiny and neat. The problem was that sooner rather than later you needed to change from chrome to plastic pipework and that was never, ever, a nice, shiny or neat change.

You really only had two options: fit the chrome into plastic push-fit pipework or use a compression connector.

The problem with using plastic push-fit is that it's not really designed for this diameter of pipe and, whilst chrome pushes-into push-fit fittings easily enough, it also pulls back out again with little or no encouragement. This is bad enough when you can see the problem but when you hide the push-fit behind stud walls and under floorboards you are just asking for trouble.

Compression fittings aren't much better because they are huge and ugly and, once again, the chrome pipework can be pulled out again fairly easily - because the chrome pipework is slightly narrower and because chrome is pretty slippy stuff.

To add to the frustration, what you wanted your chrome pipework to join to - solvent-weld plastic - it obstinately refused to do so.

The end result was that I avoided Chrome pipework like the plague. Sadly, whilst the Black Death hasn't darkened my doorstep since the 1600's, Chrome keeps cropping up all the bloody time and has to be dealt with.

Fortunately those lovely people at McAlpine have come to the rescue with a series of fittings designed specifically for chrome waste pipework. This includes general chrome fittings, designed specifically for Chrome Waste pipework, lengths of chrome pipe itself and, most importantly of all, adaptors to take you from chrome to solvent weld neatly and easily.

I can sleep well at night once more :)